Determination of urinary S-phenylmercapturic acid by HPLC and LC/MS: a comparison of the two methods.

Xiang Hong,Ye Yujie,Song Shizhen,Ye Fangli,Chen Siqi,M. Yong
Abstract:[Objective] To compare the validity of HPLC and LC/MS analysis of urinary S-phenylmercapturic acid(SPMA)so as to assess the feasibility of HPLC method in measuring SPMA.[Methods] The urine samples were acidified by 50% sulfuric acid and pretreated by liquid-liquid extraction using chloroform : isopropyl alcohol(5 : 1,v/v).The residue dissolved with methanol was injected in ODS-3 column for SPMA separation,followed by ultraviolet detector and LC/ESI-NI/ MS analysis,respectively.Paired measurements were applied to the analysis of 86 urine samples from workers occupationally exposed to benzene.HPLC results were evaluated by comparison with the LC/MS analysis.[Results] The limits of detection of HPLC and LC/MS were 40 μg/L and 5 μg/L,respectively.Retention time of SPMA peak appear at about 31 min and 7.8 min,respectively.13 of 86 samples in HPLC analysis were assigned as false-positives.HPLC results compared with LC/MS data showed to overestimate SPMA concentrations of about 8%-21% and a correlation coefficient of 0.915 was calculated between the two methods.[Conclusion] HPLC analytical method is suitable for preliminary screening of urinary SPMA in routine biomonitoring for benzene-exposed workers,while LC/MS could be an more accurate quantitative determination method for measuring urinary SPMA concentration.
Medicine,Chemistry