Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid

Zheyu Wang,Jingyi Luan,Anushree Seth,Lin Liu,Minli You,Prashant Gupta,Priya Rathi,Yixuan Wang,Sisi Cao,Qisheng Jiang,Xiao Zhang,Rohit Gupta,Qingjun Zhou,Jeremiah J. Morrissey,Erica L. Scheller,Jai S. Rudra,Srikanth Singamaneni
DOI: https://doi.org/10.1038/s41551-020-00672-y
IF: 28.1
2021-01-01
Nature Biomedical Engineering
Abstract:The detection and quantification of protein biomarkers in interstitial fluid is hampered by challenges in its sampling and analysis. Here we report the use of a microneedle patch for fast in vivo sampling and on-needle quantification of target protein biomarkers in interstitial fluid. We used plasmonic fluor—an ultrabright fluorescent label—to improve the limit of detection of various interstitial fluid protein biomarkers by nearly 800-fold compared with conventional fluorophores, and a magnetic backing layer to implement conventional immunoassay procedures on the patch and thus improve measurement consistency. We used the microneedle patch in mice for minimally invasive evaluation of the efficiency of a cocaine vaccine, for longitudinal monitoring of the levels of inflammatory biomarkers, and for efficient sampling of the calvarial periosteum—a challenging site for biomarker detection—and the quantification of its levels of the matricellular protein periostin, which cannot be accurately inferred from blood or other systemic biofluids. Microneedle patches for the minimally invasive collection and analysis of biomarkers in interstitial fluid might facilitate point-of-care diagnostics and longitudinal monitoring.
engineering, biomedical
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the challenges faced in detecting and quantifying protein biomarkers in interstitial fluid (ISF). Specifically, the author points out that current technologies have difficulties in extracting ISF, such as being time - consuming, requiring large - scale instruments, and having a small extraction volume, which makes comprehensive analysis difficult. In addition, since the concentration of protein biomarkers in ISF is usually lower than that in blood, and the slow diffusion speed of target molecules to the sensor surface due to the dense tissue environment, these factors further reduce the capture probability of target molecules and the corresponding signal intensity, thus exacerbating the difficulty of detecting protein biomarkers in ISF. Although progress has been made recently in multiplex biomarker detection, the sensitivity of existing microneedle - based analytical methods is still insufficient to detect or quantify most ISF protein biomarkers, limiting the development potential of diagnostic tests based on ISF biomarker levels. To solve these problems, this paper proposes a microneedle - patch - based technology for ultrasensitive and quantitative measurement of target protein biomarkers in ISF. By using an ultra - bright fluorescent label - plasmonic fluor, this technology has increased the detection limit of various ISF protein biomarkers by nearly 800 times, and has implemented the traditional immunoassay procedure on the patch through a magnetic back layer, thereby improving the consistency of measurement. This microneedle - patch technology can not only achieve rapid in - vivo sampling and on - needle quantitative analysis, but also has the characteristics of being minimally invasive and simple to operate, and is suitable for point - of - care diagnosis and longitudinal monitoring.