Modified surface measurement method to determine catheter tip position of totally implantable venous access port through right subclavian vein

Chenfei Zhou,Li Lu,Liu Yang,Wenqi Xi,Tao Ma,Chen Yang,Junwei Wu,Chengfang Shangguan,Zhenggang Zhu,Jun Zhang
DOI: https://doi.org/10.1016/j.jvsv.2020.07.004
2021-03-01
Abstract:<h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Background</h3><p>Optimal catheter tip position of totally implantable venous access port (TIVAP) is important to maintain its function and to avoid severe complications. In the present study, we aimed to assess the reliability of a modified surface measurement method to determine optimal tip position of a TIVAP catheter inserted through the right subclavian vein.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Patients and methods</h3><p>Clinical and radiological information of 105 patients who underwent TIVAP implantation through right subclavian vein were collected retrospectively. The length of implanted catheter was determined by a modified surface measurement method described as following. Distance from puncture point (point A) to middle point of sternal notch (point B), then middle point of sternal notch (point B) to middle point of Loui's angle (point C) was added up. The equation for the catheter length is given by: catheter length (cm) = AB + BC + 3. Post-procedure plain chest radiography (CXR) and enhanced chest computer tomography (CT) were used to check the catheter tip position and calculate optimal position rate. Distance from carina to catheter tip and length of vertebral body unit (VBU) was measured on both CXR and CT. Distance from carina to caval-atrial junction (CAJ) and catheter tip to CAJ was measured on CT.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Results</h3><p>Mean length of implanted catheter of all patients was 17.0±0.7cm (male vs. female, 17.3±0.5cm vs. 16.7±0.7cm, <em>P</em>&lt;0.001). On CXR test, catheter tip located within 2.4 VBUs below carina was identified as optimal position, and the optimal position rate was 97.1% (102/105 cases). On CT test, two definitions of optimal position were used (First, within 2cm above or below CAJ; Second, within 2cm above or at CAJ), and the optimal position rate was 92.4% (97/105 cases) and 78.1% (82/105 cases), respectively. Median follow-up time was 9.4 months. During the follow-up, no severe cardiac related complication was recorded.</p><h3 class="u-h4 u-margin-m-top u-margin-xs-bottom">Conclusion</h3><p>The modified surface measurement had a high reliability when determining the optimal catheter length to accurately place the tip in the SVC near the cava-atrial junction.</p>
surgery,peripheral vascular disease
What problem does this paper attempt to address?