Development of an Automated Capture-SELEX Device for Efficient Screening of Β-Conglycinin Aptamer.

Yingming Zhang,Shikun Zhang,Zhiyuan Ning,Xianfeng Lin,Nuo Duan,Zhouping Wang,Shijia Wu
DOI: https://doi.org/10.1021/acs.jafc.4c10043
IF: 6.1
2024-01-01
Journal of Agricultural and Food Chemistry
Abstract:β-Conglycinin is the main allergen present in soybeans, and it is causing wide concern due to its notable allergenicity, heat, and digestive enzyme resistance. Screening for aptamers that both recognize β-conglycinin and inhibit the allergic reactions that it triggers is necessary. Conventional aptamer screening is labor-intensive, requires skilled personnel, and has limited reproducibility. To address these limitations, an automated device was developed to enhance the efficiency of aptamer selection in Capture-SELEX. The device achieves highly integrated, reproducible, and accurate contamination control. Using this device, a high-affinity and specific aptamer, β-5, was selected with a Kd = 18.24 ± 2.42 nM for β-conglycinin, as confirmed by isothermal titration calorimetry and fluorescence polarization. Thermodynamic analysis revealed that enthalpy-driven binding and docking simulations clarified the recognition mechanism. Overall, this automated device enables high-efficiency aptamer generation for certain targets, with aptamer β-5 expected to play a vital role in the detection of β-conglycinin and the targeted inhibition of its allergic reaction.
What problem does this paper attempt to address?