Adaptive Dual-Harmonic Switching WMS for CO2 Measurement over a Wide Dynamic Range

Zifei Li,Yunfan Hu,Xianyi Wang,Guojie Tu,Benli Yu,Sheng Zhou
DOI: https://doi.org/10.1109/jsen.2024.3494799
IF: 4.3
2024-01-01
IEEE Sensors Journal
Abstract:A Dual-Harmonic Switching Wavelength Modulation Spectroscopy (DHS-WMS) technique has been proposed for gas sensing. The optimal signal-to-noise ratio (SNR) is achieved by adaptively switching harmonic signals based on gas concentrations. To implement the DHS-WMS technique, a gas sensing system with a specific absorption transition at 1572.33654 nm for CO 2 detection and an effective optical absorption length of 3.3 m has been established. Typically, atmospheric greenhouse gas CO 2 , with concentrations ranging from 5% to 60%, was selected as the target analyte to evaluate the performance of DHS-WMS. Subsequently, the baseline fluctuation and signal-to-noise ratio of the 2f and 4f signals were analyzed in detail. In cases of wide concentration variations, the strategy of switching between different harmonic detection techniques proved superior to using a single harmonic detection method. The results indicate that the DHS-WMS technique, dynamically adjusting harmonic orders, outperforms traditional WMS with fixed harmonics, especially across a wide concentration range. The minimum detection limit (MDL) for CO 2 has been determined to be 26.7 ppm at an integration time of 52 s, based on the Allan variance analysis. DHS-WMS, with its capacity for high sensitivity and extensive measurement ranges, holds tremendous potential for applications in urban air quality monitoring and industrial emission control.
What problem does this paper attempt to address?