Noninvasive Evaluation of Lupus Nephritis Activity Using a Radiomics Machine Learning Model Based on Ultrasound
DOI: https://doi.org/10.2147/JIR.S398399
IF: 4.5
2023-02-03
Journal of Inflammation Research
Abstract:Xiachuan Qin, 1, 2, &ast Linlin Xia, 1, &ast Chao Zhu, 3 Xiaomin Hu, 2 Weihan Xiao, 2 Xisheng Xie, 4 Chaoxue Zhang 1 1 Department of Ultrasound, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, People's Republic of China; 2 Department of Ultrasound, Nanchong Central Hospital, The Second Clinical Medical College, North Sichuan Medical College (University), Nan Chong, Sichuan, People's Republic of China; 3 Department of Radiology, The First Affiliated Hospital of Anhui Medical university, Hefei, Anhui, People's Republic of China; 4 Department of Nephrology, Nanchong Central Hospital, The Second Clinical Medical College, North Sichuan Medical College (University), Nan Chong, Sichuan, People's Republic of China &astThese authors contributed equally to this work Correspondence: Chaoxue Zhang, Department of Ultrasound, The First Affiliated Hospital of Anhui Medical University, Hefei, Anhui, People's Republic of China, Email Xisheng Xie, Department of Nephrology, Nanchong Central Hospital, The Second Clinical Medical College, North Sichuan Medical College (University), Nan Chong, Sichuan, People's Republic of China, Email Introduction: To explore whether ultrasonic radiomics extracted by machine learning method can noninvasively evaluate lupus nephritis (LN) activity. Materials and Methods: This retrospective study included 149 patients with LN diagnosed by renal biopsy. They were divided into a training cohort (n=104) and a test cohort (n=45). Ultrasonic radiomics features were extracted from the ultrasound images, and the radiomics features were constructed. Furthermore, five machine learning algorithms were compared to evaluate LN activity. The performance of the binary classification model was evaluated by the area under the receiver operating characteristic curve (AUC), accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results: The average AUC of the five machine learning models was 79.4, of which the MLP model was the best. The AUC of the training group was 89.1, with an accuracy of 81.7%, a sensitivity of 83%, a specificity of 80.7%, a negative predictive value of 85.2%, and a positive predictive value of 78%. The AUC of the test group was 82.2, the accuracy was 73.3%, the sensitivity was 78.9%, the specificity was 69.2%, the negative predictive value was 81.8%, and the positive predictive value was 65.2%. Conclusion: Machine learning classifier based on ultrasonic radiomics has high accuracy for LN activity. The model can be used to noninvasively detect the activity of LN and can be an effective tool to assist the clinical decision-making process. Keywords: systemic lupus erythematosus, lupus nephritis, activity, ultrasound, machine learning Lupus nephritis (LN) is a common complication of systemic lupus erythematosus (SLE). The severity of renal damage is closely related to the prognosis of SLE. Renal involvement and progressive renal dysfunction are one of the main causes of death in SLE. 1,2 LN causes renal damage by deposition of circulating or in situ immune complexes. 3 The goal of LN treatment is to eliminate active inflammation and achieve renal remission and disease quiescence. 4 Currently, renal biopsy is the gold standard for diagnosis and treatment of LN. 5 It is also the only way to judge disease activity. 6,7 When the treatment of LN is inadequate or if LN relapses, it is often necessary to repeat renal biopsy to accurately judge pathological changes and formulate corresponding treatment plans. 8 However, renal biopsy is an invasive diagnosis with the risk of bleeding. Repeated renal biopsy is difficult to be accepted by patients. Therefore, a noninvasive method is urgently needed to accurately determine the activity of LN. Ultrasound is the most commonly used imaging method to understand the renal morphology, and the ultrasonic performance reflects the chronic pathological changes of the kidney. 9 However, as LN tends to be more normal in the ultrasonic graphic performance, there is no study to evaluate the activity of LN by imaging examination currently. We assume that changes in LN activity can be detected by advanced computing technologies (such as radiomics). Radiomics obtains multiple quantitative features from single or multiple medical imaging modes, highlighting image features that are not visible to the naked eye. 10 Machine learning technology (ML) shows the ability of high sensitivity, high-dimensional information mining and high-throughput computing, and has more important valu -Abstract Truncated-
immunology