Synthesis and Bioimaging Application of Near-infrared II Fluorescence Nanoprobes
Jin-wen Peng,Xiao-long Du,Yan Chen,Peng-fei Sun,Wei-xing Deng,Qu-li Fan
DOI: https://doi.org/10.11777/j.issn1000-3304.2020.20076
2020-01-01
Acta Polymerica Sinica
Abstract:Fluorescence imaging in the second near-infrared window (NIR-II) holds promise for real-time deep tissue imaging. In this work, we design a low-band gap conjugated polymers(pTB) with donor-acceptor (D-A) structures by Stille cross-coupling reaction, which can improve the quality of fluorescence imaging and effectiveness of photothermal therapy. In order to improve the water solubility and biocompatibility of pTB, we adopted nano-deposition technology to envelop the hydrophobic polymer p113 into amphiphilic copolymer (1,2-distearoyl-phosphatidylethanolamine-methyl-polyethyleneglycol conjugate (DSPE-mPEG)) shells for NIR-II water-soluble nanoparticles (p113-PEG). The structure, properties and morphology of the polymer were analyzed by 1H-NMR, UV-Vis, dynamic light scattering (DLS) and transmission electron microscopy (1EM). The results show that the conjugated polymer nanoparticles have not only a good absorption peak at 831 nm, but also a large Stokes shift of 206 nm. In addition, the average hydrodynamic radius of pTB-PEG NPs was around 69 nm and spherical morphology was observed from TEM. And the nanoparticles also possess excellent photostability and good biocompatibility in physiological environment such as phosphate buffer saline (PBS), Dulbecco's Modified Eagle Medium (DMEM) and fetal bovine serum (FBS), indicating the potential for further in vivo application. More importantly, we used MTT assay to analyze photothermal treatment toward human breast cancer (4T1) cells in vifro, and confocal laser scanning microscopy (CLSM) tests further indicated that this material has a good photothermal therapeutic effect. To study the NIR-II fluorescence characters, we firstly detected the maximum imaging depth of pTB-PEG NPs in vifro. With the help of long-wavelength emission (>1000 nm), the imaging depth is 6 mm, far exceeding the traditional near-infrared region (NIR-I) reagents. Under 808 nm laser irradiation, the high-resolution second near-infrared window (NIR-II) fluorescence imaging of healthy mouses' blood vascular system and tumor-bearing mice was effectively achieved. In general, conjugated polymer nanoparticles (pTB-PEG) have a good biocompatibility, excellent light stability and good optical properties. It is a promising NIR-II imaging probe with a wide range of the potential for clinical imaging and live tumor imaging.