Comparative study of interfacial properties and thermal behaviour of milk fat globules and membrane prepared from ultrasonicated bovine milk

Yanjun Sun,Yrjö H Roos,Song Miao,Yrjö H. Roos
DOI: https://doi.org/10.1016/j.ultsonch.2024.106755
IF: 9.336
2024-01-10
Ultrasonics Sonochemistry
Abstract:Milk fat globules or milk fat globule membranes (MFGs/MFGM) have been added in the infant formula to fortify the phospholipids and narrow down the nutritional gap from breast milk. The main aim of this study was to profile the interfacial and thermal properties of MFGs/MFGM prepared from ultrasonicated bovine milk. Bovine milk was sonicated at ultrasonic intensities of 20 kHz and 40 kHz independently or synchronously with the duration time of 0 min (control), 5 min, 10 min and 15 min (work/rest cycles = 5 s: 3 s). Ultrasonic treatments at 20 kHz/ 5 min and 20 + 40 kHz/ 5 min improved the volume density (%) of smaller particles (1–10 μm), while significantly decreased the surface hydrophobicity (H 0 ) (p < 0.05). 40 kHz/5 min samples showed significantly higher ζ- potential than the other samples (p < 0.05), which might be because more negative charges were detected. In comparison with control samples, ultrasonic treatments decreased the interfacial tension (π) between the air and MFGs/MFGM liquid phase. 20 kHz ultra-sonicated treatments decreased the diffusion rate ( k diff ) of MFGs/MFGM interfacial compositions significantly as the duration prolonged from 5 min to 15 min (p < 0.05) but did not affect the adsorption or penetration rate ( k a ) (p > 0.05). X-ray diffraction (XRD) results showed that α-crystal peaks only existed in control and ultrasonicated 5 min samples, but disappeared in all 15 min samples. According to the different scanning calorimetry (DSC), one or two new exothermic events (in the range of 17.29 – 18.81 °C and 22.14 – 25.21 °C) appeared after ultrasonic treatments which, however, were not found in control samples. Ultrasonic treatments resulted in the low-melting fractions (LMF) (T M1 ) peaks undetectable in MFGs/MFGM samples in which only peaks of medium-melting fractions (MMF) (T M2 ) and high-melting fractions (HMF) (T M3 ) were detected. Compared with the control, both enthalpy of crystallisation (ΔH C ) and melting (ΔH M ) decreased in ultrasonicated samples. In conclusion, ultrasonic treatment affects the interfacial and thermal properties of MFGs/MFGM.
chemistry, multidisciplinary,acoustics
What problem does this paper attempt to address?