Investigation of the Influence of Different Control Strategies on the Part Load Performance for the R-Graz Cycle

Shida Yu,Xiaodong Ren,Bo Hu,Chunwei Gu
DOI: https://doi.org/10.33737/gpps24-tc-036
2024-01-01
Abstract:In the context of large-scale hydrogen energy utilization for power generation, the R-Graz cycle has demonstrated remarkable performance and technological feasibility. To meet the requirements of grid supply, it is imperative to develop appropriate control strategies to achieve stable and efficient operation. In addition to the conventional control parameters such as fuel and IGV adjustments, there exists an additional control parameter called split ratio. In this study, various control strategies were formulated and performance analyses were conducted for the R-Graz cycle. The results indicate that the control strategy aiming to maintain the turbine inlet temperature outperforms the strategy aiming to maintain the exhaust temperature in terms of efficiency. Within the control strategy focused on maintaining the turbine inlet temperature, the inventory control strategy demonstrates superior efficiency compared to the split ratio and IGV control strategies. By integrating the advantages of various control strategies, a hybrid inventory control strategy suitable for the R-Graz cycle is proposed. At 40% load, the efficiency is about 87.1% of the design point, surpassing conventional F-class combined cycle units.
What problem does this paper attempt to address?