Consistency of electrical source imaging in presurgical evaluation of epilepsy across different vigilance states

Tamir Avigdor,Chifaou Abdallah,Jawata Afnan,Zhengchen Cai,Saba Rammal,Christophe Grova,Birgit Frauscher
DOI: https://doi.org/10.1002/acn3.51959
IF: 5.43
2024-01-14
Annals of Clinical and Translational Neurology
Abstract:Objective The use of electrical source imaging (ESI) in assessing the source of interictal epileptic discharges (IEDs) is gaining increasing popularity in presurgical work‐up of patients with drug‐resistant focal epilepsy. While vigilance affects the ability to locate IEDs and identify the epileptogenic zone, we know little about its impact on ESI. Methods We studied overnight high‐density electroencephalography recordings in focal drug‐resistant epilepsy. IEDs were marked visually in each vigilance state, and examined in the sensor and source space. ESIs were calculated and compared between all vigilance states and the clinical ground truth. Two conditions were considered within each vigilance state, an unequalized and an equalized number of IEDs. Results The number, amplitude, and duration of IEDs were affected by the vigilance state, with N3 sleep presenting the highest number, amplitude, and duration for both conditions (P 0.05). ESI maps showed no differences in distance, quality, extent, or maxima distances compared to the clinical ground truth for both conditions (P > 0.05). Only when an absolute reference (wakefulness) was used, the channel involvement (P
neurosciences,clinical neurology
What problem does this paper attempt to address?