Cosmic Ray Test of Shashlik Electromagnetic Calorimeter Modules for NICA-MPD

Xi-Yang Wang,Shuai-Chun Wang,Wan-Bing He,Yu-Gang Ma
DOI: https://doi.org/10.1016/j.nima.2024.169857
2024-01-01
Abstract:The electromagnetic calorimeter (ECal) plays a critical role in high-energy particle colliders, by measuring the energy of particles that interact primarily via the electromagnetic interaction such as electrons, positrons and photons. Fudan University has undertaken part of the mass production of ECal modules for the Multi-Purpose Detector (MPD) project of the Nuclotron-based Ion Collider fAcility (NICA). Preliminary tests on the ECal modules is an essential step in detector construction. This article introduces the cosmic ray testing of the ECal modules produced by Fudan University. We tested the cosmic ray under the conditions of horizontal and vertical placement of the module, calculated the average number of generated photons, and estimated the module's energy resolution. Moreover we analyzed the time resolution performance of the device. The test results indicate that when cosmic rays vertically traverse the entire ECal, the number of photons produced can reach 834, with a potential energy resolution less than 5%/root E . The time resolution is 189ps. Based on the comprehensive test results, the production of the ECal meets the design requirements.