Micro fl uidic Device with Integrated Biosensors for Online Analysis of Subcutaneous Human Microdialysate
Sally A. N. Gowers,Vincenzo F. Curto,Carlo A. Seneci,Chu Wang,Salzitsa Anastasova,Pankaj Vadgama,Guang-Zhong Yang,Martyn G. Boutelle
2015-01-01
Abstract:This work presents the design, fabrication, and characterization of a robust 3D printed microfluidic analysis system that integrates with FDA-approved clinical microdialysis probes for continuous monitoring of human tissue metabolite levels. The microfluidic device incorporates removable needle type integrated biosensors for glucose and lactate, which are optimized for high tissue concentrations, housed in novel 3D printed electrode holders. A soft compressible 3D printed elastomer at the base of the holder ensures a good seal with the microfluidic chip. Optimization of the channel size significantly improves the response time of the sensor. As a proof-of-concept study, our microfluidic device was coupled to lab-built wireless potentiostats and used to monitor real-time subcutaneous glucose and lactate levels in cyclists undergoing a training regime. W sensors connected to body sensor networks (BSN) that provide real-time information about the wearer’s health and fitness are of great interest both academically and commercially. Developments of such platforms have mainly focused on sensors that measure physical vital signs (e.g. pulse rate, ECG). Biosensors targeting physiologically relevant analytes are more challenging but can provide important information about tissue health and fitness, allowing, for example, athletes to tailor their training to their individual characteristics, enabling them to assess their training effectiveness, to make adjustments, and to track improvements in their performance. Extensive research efforts have focused on the development of miniaturized on-body chemo/biosensors for the measurement of physiological analytes in different bodily fluids, such as interstitial fluid, sweat, tears, and saliva. Glucose and lactate are particularly attractive biomarkers to monitor as they provide information about tissue energy metabolism. Lactate, in particular, has received much interest for sports monitoring. During intense exercise, tissue oxygen levels are insufficient for aerobic metabolism to meet the energy demands of the body. Instead, anaerobic metabolism occurs to meet these increased energy demands, leading to elevated lactate levels. Lactate can therefore be used as a measure of how hard the body is working, allowing athletes to modulate their effort accordingly, in order to train the body to increase its efficiency in clearing excess lactate or to avoid causing damage by overtraining. Commercially available blood lactate and glucose meters are used for sports applications. Although blood measurements provide important information about global metabolite levels in the body, the use of finger-prick test strips has several limitations. The main limitation of discrete sampling is the lack of temporal resolution, with the result that it is not possible to observe dynamic changes in metabolite levels. In order to improve temporal resolution blood samples have to be taken regularly, resulting in constant interruptions during the activity period. In contrast, online microdialysis allows continuous monitoring of tissue metabolites, which, when coupled with an online analysis system, provides good temporal resolution, suitable for resolving dynamic changes. The microdialysis probe consists of a semipermeable membrane that is perfused with a solution that matches the extracellular fluid. Formation of a concentration gradient across the membrane allows exchange of molecules between the probe and the tissue, creating a dialysate stream that can be analyzed for compounds of interest. Microdialysis has been used in a wide range of applications and is an attractive technology for human in vivo monitoring, as commercial FDA-approved probes are available. Microdialysis combined with online analysis systems has been used extensively to detect tissue health and ischemic events. In particular, the lactate/glucose ratio has been shown to be an especially sensitive marker of tissue health, providing a clear indication as to whether tissue energy demands are being met. There is a natural synergy between microdialysis and microfluidic devices because high time resolution analysis of low volume flow rates requires very small internal Received: April 10, 2015 Accepted: June 12, 2015 Published: June 12, 2015 Article