Transient Simulation on Flow and Heat Transfer Characteristics of Aeroengine Fuel-Oil Thermal Management System

Shiyu Yang,Yuanfang Lin,Xianghua Xu,Xingang Liang
DOI: https://doi.org/10.1007/978-981-97-4010-9_21
2024-01-01
Abstract:In order to improve the transient performance of aeroengine fuel-oil thermal management system, a simulation program was developed based on Python language and a complete flight mission profile was calculated. The results indicate that the increase of hot fuel return will drop the inlet pressure of engine fuel pump, however, the fuel supply to combustor remains unchanged. In the ground hold stage, the engine fuel pump circuit heats the fuel the most severely. During the whole flight, the system thermal load is mainly dispersed by combustion fuel and only 18.7% dispersed by air. Viscous dissipation heat of resistance components accounts for 78.3% of the additional thermal load, of which the influence on system temperature cannot be ignored. Further, the additional thermal load increases rapidly when taking off and the heat dissipation effect of the hot fuel return mainly occurs in the late stage of the flight process. Finally, the area ratio influence of air heat exchangers was studied. The results show that when the total area of air heat exchangers is constant, the opening time of the thermal management valve is delayed by the aera increase of the air-oil heat exchanger and the hot fuel return will be reduced, which can improve the system heat dissipation capacity.