In Situ Fabrication of Cu2O Array Electrode for Efficient Detection of Acetaminophen

Xiaoying Wang,Jiaqiang Liu,Yuanxia Zuo,Ying Fan,Zhiheng Zhang,Chengyan Zhang,Fan Zhang,Mingyan Wang,Ruibo Xu
DOI: https://doi.org/10.1142/s1793604724510457
IF: 1.4901
2024-01-01
Functional Materials Letters
Abstract:In this paper, Cu(OH)2 nanosheet arrays were directly grown in an upright manner on the surface of copper foam (CF) through a simple solvent reaction, followed by the successful reduction of Cu(OH)2 into Cu2O using hydrazine hydrate vapor, resulting in a binder-free Cu2O@CF array electrode. The in situ growth technique guarantees robust bonding between Cu2O and the conductive substrate, thereby enhancing electron transfer among various electrode components. Additionally, the vertically aligned array structures facilitate rapid penetration and transfer of the analyte, while also allowing for thorough exposure of the electroactive surfaces to the electrolyte. When utilized as an adhesive-free biosensor, the obtained Cu2O@CF array electrode exhibited sensitive catalytic oxidation activity toward acetaminophen (AP), providing a wide linear range of 2-200 mu M and a low detection limit of 0.6 mu M for AP detection. Furthermore, the developed Cu2O@CF array electrode was successfully utilized to detect AP in medicine samples. With its simple fabrication method, broad linear range, low detection limit, and excellent stability, this electrode holds significant promise for the detection of AP in pharmaceuticals.