Identification of remnant OCT media artifacts after tissue washing by MALDI mass spectrometry imaging

Kevin Zemaitis,Rashmi Kumar,Marija Veličković,Dušan Veličković,Wei-Jun Qian,Ljiljana Paša-Tolić
DOI: https://doi.org/10.26434/chemrxiv-2024-m536q
2024-09-16
Abstract:RATIONALE Universally, the most common method of embedding dissected or resected fresh frozen (FF) tissues is within optimal cutting temperature (OCT) media. Unfortunately, OCT is not ideal for mass spectrometry (MS) assays. The media perfuses through tissues, resulting in persistent polymer contamination causing issues for sensitive analyses. Complete removal of all OCT media background would enable techniques such as MS imaging (MSI) to be bridged to clinically relevant samples stored in biobanks which possess extensive medical histories. Even though methods have been outlined for spatial lipidomics and proteomics, many still avoid these tissues despite vast potential for biological discoveries applying MS or MSI. METHODS Reference FF human pancreas was prepared within OCT media and cryosectioned for matrix-assisted laser desorption/ionization (MALDI)-MSI. Sample preparation protocols using aqueous ammonium formate for spatial lipidomics, and a variety of solutions for fixation, delipidation, and salt removal enabled spatial proteomics as well. MSI was performed on a UHMR HF Orbitrap MS detected broad classes of lipids and intact proteins, enabling an assessment of polymer perfusion and signal delocalization over a broad mass range to evaluate any deleterious artifacts. RESULTS We observe lower polymer contamination from OCT tissues with ammonium formate washes as expected, with several caveats. This was most effective in negative ion mode, where in tandem with the boosted lipid signal positive results were achieved for phospholipids (600-900 Da) and higher mass lipids (>1250 Da). Positive ion mode analyses can be completed for phospholipids, but the condensation of alkali adducts to protonated forms not only increased lipid signals, but also increased signals of larger, persistent PEG oligomers (>1250 Da) which were not previously reported. Even with extensive tissue washing completing a spatial proteomics protocol, the removal of all remnant artifacts of OCT media was not feasible. CONCLUSIONS The finding of these persistent remnant polymers from the OCT embedding process has several consequences for MSI, directly effecting primary performance of the MALDI source and lipid and protein analyses. This does not mean OCT tissues should not be or cannot be used for spatial omics by MSI, but several quality control and quality assurance measures should be implemented, and we discuss paths forward and several considerations.
Chemistry
What problem does this paper attempt to address?
### Problems Addressed by the Paper This paper primarily explores how to effectively remove OCT (Optimal Cutting Temperature) medium residues when using it to cryo-fix tissue samples for mass spectrometry imaging (MSI) analysis. Specifically, the paper focuses on the following aspects: 1. **Impact of OCT Medium Residues on MSI**: - Polymers in the OCT medium (such as polyvinyl alcohol and polyethylene glycol) can infiltrate the tissue, causing persistent contamination and affecting high-sensitivity analysis. - Completely removing all OCT medium background can enable the application of MSI technology to clinically relevant biological samples. 2. **Evaluation of Existing Methods**: - Using ammonium formate washing can reduce polymer contamination from the OCT medium, especially effective in negative ion mode. - However, in positive ion mode, some high molecular weight polyethylene glycol oligomers still persist and signal enhancement occurs. 3. **Applications in Spatial Lipidomics and Proteomics**: - Although ammonium formate washing can improve the signal intensity of phospholipids (600-900 Da) and high molecular weight lipids (>1250 Da), completely removing OCT medium residues remains challenging. - Spatial proteomics experiments indicate that even after prolonged washing steps, residues from the OCT medium cannot be entirely removed. 4. **Quality Control and Assurance Measures**: - Several quality control and assurance measures are proposed to mitigate the impact of OCT medium residues on MSI analysis. - It is recommended to avoid analyzing the tissue edge areas and to handle analyses in positive ion mode with caution. Through these studies, the paper aims to provide guidance and improvement plans for future MSI analysis of tissue samples cryo-fixed with OCT medium.