Adaptability and Environmental Impact of CO2/R41 Mixture in Heat Pump Air Conditioning Systems for Electric Vehicles

Bo Tang,Hongsheng Jiang,Weilin Zhuge,Lei Sun
DOI: https://doi.org/10.1016/j.applthermaleng.2024.123463
IF: 6.4
2024-01-01
Applied Thermal Engineering
Abstract:The development of energy -efficient and environmentally friendly next -generation refrigerants is crucial for electric vehicle mobile heat pump air conditioning systems, with the CO2/R41 mixture being a preferred alternative. In this paper, firstly, within the framework of energy conservation, thermodynamic analysis was conducted to comprehensively evaluate the adaptability of CO2/R41 systems under different scenarios; subsequently, considering environmental impacts, a life cycle climate performance (LCCP) analysis was conducted to guide the selection of an appropriate CO2/R41 composition. Thermodynamic analysis indicates that the CO2/R41 mixture conducive to improving coefficient of performance (COP), reaching a maximum of 40.5 %, but as ambient temperatures become adverse, the enhancement is diminished; furthermore, the CO2/R41 mixture is more advantageous in enhancing COP at high temperatures, and at extremely low temperatures, the effect of the increased R41 component on reducing the compressor's suction density will intensify, leading to an increased demand for displacement. Results from LCCP analysis indicates that for nine typical cities in China, a CO2 mass fraction of 80 % yields the most significant LCCP reduction, with the highest being 10 % in Guangzhou.
What problem does this paper attempt to address?