Abstract:With the development of industrial and medical technology, chemical sensors based on electron charge carriers are difficult to meet the upping requirements on excellent sensitivity, good selectivity, and portability. Herein, a new type of sensing material is developed via facile preparation method. Metal ions, instead of electrons, are used as charge carriers and distributed in the polymer matrix. As a representative, the ionic conductive gas sensor based on polyacrylic acid and copper ions (PAA-Cu(II)) is fabricated. The PAA-Cu(II) sensor exhibits excellent linear response to ammonia (NH3), together with high sensitivity (50.3% for 50 ppm NH3), good selectivity, and fast response/recovery time (10/10.5 s). The sensor also displays high transparency, long-term air stability, and excellent flexibility. In addition, sensor arrays based on various metal ions (Cu2+, Co2+, Ni2+, Ag+, Fe3+, Mg2+) and polymers (polyacrylic acid, polyvinyl alcohol, polyethyleneimine) are also developed, and the sensing properties are investigated. The results suggest that metal ions-based capacitive flexible sensors have great potential for low-cost chemical sensors and provide a promising strategy for developing new sensing materials.