A Sensitive Lead-Free Perovskite Photodetector for Self-Powered Blue Light Hazard Detection Application

Xiang An,Zhi-Guo Zhu,Zheng Liu,Xiang Zhang,Jiang Wang,Zong-Yang Li,Li Wang,Chun-Yan Wu,Feng-Xia Liang,Ping-An Song,Lin-Bao Luo
DOI: https://doi.org/10.1109/led.2024.3394442
IF: 4.8157
2024-01-01
IEEE Electron Device Letters
Abstract:The detection of blue light hazard for artificial illuminants has become a challenging issue. In this work, a self-powered narrowband photodetector based on lead-free perovskite Cs 2 AgBiBr 6 for low-toxicity blue light hazard detection has been reported. Under zero bias, the responsivity and specific detectivity at response peak of 450 nm can reach 0.327 A/W and 2.8×10 10 Jones, respectively. In visible light, the photodetector is only sensitive to blue light with a rejection ratio (450/510 nm) of 28.4, effectively suppressing the influence of other visible light without filters. Then an error factor is introduced to establish a relationship between the blue light weighted radiance and photocurrent. By integrating with the back-end circuit, a portable detection system is demonstrated, which can smartly evaluate the blue light hazard level of artificial illuminants. We believe that such highly sensitive and lead-free features render it a promising candidate for human eyes protection in the field of green healthcare.
What problem does this paper attempt to address?