Insertion site and risk of peripheral intravenous catheter colonization and/or local infection: a post hoc analysis of the CLEAN 3 study including more than 800 catheters

Bertrand Drugeon,Nicolas Marjanovic,Matthieu Boisson,Niccolò Buetti,Olivier Mimoz,Jérémy Guenezan
DOI: https://doi.org/10.1186/s13756-024-01414-4
IF: 6.454
2024-06-08
Antimicrobial Resistance and Infection Control
Abstract:Although uncommon, infections associated with peripheral intravenous catheters (PIVCs) may be responsible for severe life-threatening complications and increase healthcare costs. Few data are available on the relationship between PIVC insertion site and risk of infectious complications.
infectious diseases,public, environmental & occupational health,microbiology
What problem does this paper attempt to address?
This paper aims to explore the relationship between peripheral intravenous catheter (PIVC) insertion sites and the risk of infection. Specifically, the researchers conducted a post-hoc analysis of the external database CLEAN 3 to evaluate the impact of different PIVC insertion sites on catheter colonization and local infection risk. The study found that inserting PIVCs at the antecubital fossa or wrist increases the risk of catheter colonization and local infection, as well as the risk of positive PIVC tip cultures. Therefore, the study recommends avoiding PIVC insertion at these sites when possible to reduce the occurrence of infectious complications.