Novel traction device for endoscopic submucosal dissection: a rotatable transparent cap, an additional channel, and a traction wire
Xi Chen,Zhenqun Lin,Xiangqing Li,Xiaoning Yang,Wenjuan Liu,Zehui Huang,Shuntian Cai
DOI: https://doi.org/10.1055/a-2222-6958
2024-01-25
Endoscopy
Abstract:Traditionally, endoscopic procedures have been limited to a single–channel device, making it difficult for endoscopists to perform endoscopic submucosal dissection (ESD). As a result, several solutions have been developed, each with its own advantages and disadvantages, including traction devices [1] [2], double-channel endoscopes [3], laparoscopy–endoscopy combined surgery [4], and surgical endoscopic robots [5]. To address these challenges, we fabricated a rotatable transparent cap with a fixed channel that can accommodate endoscopic surgical instruments. The traction device consists of three components: a rotatable transparent cap, an additional channel, and a traction wire ([Fig. 1]). The additional channel and traction wire are connected to a rotatable ring on the transparent cap. By pulling the traction wire, the additional channel can be rotated around the transparent cap ([Fig. 1]). During ESD, foreign-body forceps are inserted into the additional channel to clamp and push the tumor to the distal end, acting as a traction device. During the operation, the position of the additional channel can be controlled dynamically by pulling the traction wire. To assess the efficacy of this device, we performed ESD in four directions: downward, upward, leftward, and rightward. The results demonstrated that this rotatable transparent cap device enables dynamic rotation of the foreign-body forceps in various directions to apply traction ([Video 1]). This not only decreases the complexity of the procedure and the associated risks, but also leads to a significant reduction in operation time and incidence of complications. In conclusion, this device exhibits promise for facilitating traction during ESD, simplifying the procedure and eliminating the need for specialized endoscopic equipment. Endoscopy_UCTN_Code_TTT_1AQ_2AD E-Videos is an open access online section of the journal Endoscopy , reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high-quality video and are published with a Creative Commons CC-BY license. Endoscopy E-Videos qualify for HINARI discounts and waivers and eligibility is automatically checked during the submission process. We grant 100% waivers to articles whose corresponding authors are based in Group A countries and 50% waivers to those who are based in Group B countries as classified by Research4Life (see: https://www.research4life.org/access/eligibility/). This section has its own submission website athttps://mc.manuscriptcentral.com/e-videos. Article published online: 23 January 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
gastroenterology & hepatology,surgery