Research on Pulsed Eddy Current Testing Technology for Cladding Pipeline

Bo Xu,Shu-Juan Wang,Zhi-Chao Li
DOI: https://doi.org/10.1109/fendt59575.2023.10461508
2023-01-01
Abstract:Compared with traditional eddy current flaw detection, pulsed eddy current has wider frequency bandwidth and stronger penetration ability, which is often used in the detection of cladding pipes. To solve the disadvantages of low detection sensitivity and large volume of existing eddy current probes, a small probe design is proposed, which can detect surface defects under large lift-off distance. Finite element simulation and experimental tests are used to compare and analyze the influencing factors and effects of the pulsed eddy current testing. A three-dimensional finite element model is established to study the pulsed eddy current distribution and detection voltage form of the proposed probe on the specimen. Through the pulsed eddy current experiment, the detection voltage decay curve was obtained, and the peak voltage was quantitatively fitted. The experimental results show that the detection probe can effectively detect the surface square hole defect under 10mm lift-off distance. Moreover, the defect depth can be identified through the peak voltage change. The defect detection voltage curve is obtained through the defect scanning experiment, which is consistent with the simulation results.
What problem does this paper attempt to address?