Accuracy and Risk Factors of Magerl Screw Placement in Robot-Assisted Atlantoaxial Surgery: A Case Series Study

Jiayuan Wu,Yi Wei,Fangfang Duan,Da He,Xieyuan Jiang,Wei Tian
DOI: https://doi.org/10.1002/rcs.2603
2024-01-01
International Journal of Medical Robotics and Computer Assisted Surgery
Abstract:BACKGROUND:To assess the accuracy of robot-assisted Magerl screw placement and explore the factors affecting the accuracy.METHODS:A retrospective analysis of patients who underwent robot-assisted Magerl screw placement was performed. The accuracy of Magerl screw placement was evaluated according to the Gertzbein and Robbins scale.RESULTS:47 Magerl screws were placed in 24 consecutive patients. 32 Magerl screws were narrower than the C2 isthmus height and 26 of them were grade A. 15 Magerl screws were wider than the C2 isthmus height and all of them were grade B. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter were associated with a higher probability of cortical breach.CONCLUSION:The accuracy of robot-assisted Magerl screw placement was excellent. Temporary fixation after decompression and a smaller difference between the C2 isthmus height and screw diameter increased the risk of cortical breach.
What problem does this paper attempt to address?