Endovascular Salvage of Ruptured TAAA Following Stent Graft Distraction after TEVAR for Type B Aortic Dissection

Baolei Guo,Weiguo Fu
DOI: https://doi.org/10.1016/j.ejvs.2017.08.013
IF: 6.427
2017-01-01
European Journal of Vascular and Endovascular Surgery
Abstract:A 58 year old female presented with persistent back pain because of a ruptured 127 mm thoraco-abdominal aneurysm caused by migration of stent grafts with type III endoleak (A). She had undergone three episodes of hybrid open endovascular repair over the last 10 years for complicated type B and type A aortic dissections. Using percutaneous bilateral femoral access, an emergency thoracic endovascular aortic repair was undertaken using an additional stiff buddy wire with a stiff sheath to overcome the angulation. Two stent grafts [40 × 200 mm + 42 × 200 mm (Valiant Captivia, Medtronic, MN, USA)] were successfully deployed. The patient recovered well without endoleaks (B). LCCA = left common carotid artery; SMA = superior mesenteric artery; TBAD = type B aortic dissection.
What problem does this paper attempt to address?