Radiofrequency Catheter Ablation of Ventricular Arrhythmias Originating from the Epicardium Via Coronary Vein System

Mouhannad M Sadek,Francis E Marchlinski
2013-01-01
Abstract:Objective To determine the safety and efficacy of radiofrequency catheter ablation(RFCA) of frequent premature ventricular contractions(PVCs) or ventricular tachycardia(VT) originating from the epicardium via coronary vein system(CVS).Methods Twelve patients(10 men;age 49.08±15.26 years) were found to have an epicardial site of origin who were diagnosed as PVCs or VT by electrocardiogram or Holtor.Radiofrequency application could not abolish PVCs/VT during endocardial mapping and ablation.Then,the PVCs or VT originated from epicardium were considerated,so multiple electrode catheter was introduced into great cardiac vein(GCV) or anterior interventricular vein(AIV).After CVS epicardial orign for PVCs/VT had been determined by activation mapping and pace mapping,radiofrequency energy was delivered with the irrigated-tip catheter at a power of 15 to 30 W and a flow rate of 17 to 30 ml/min.Finally,the characteristics of electrocardiogram and results of ablation were analyzed.Results Ten of 12 patients underwent successful ablation within the CVS.In the 10 patients,the site of origin(SOO) of the ventricular arrhythmias was identified from within the GCV(n=7),the AIV(n=2) or the posterior lateral vein(PLV)(n=1).The mean earliest activation preceding the onset of the QRS complex was 28.67 ± 5.35 ms,and the mean impedance was 212.8±45.2 Ω.In the 2 patients with unsuccessful ablation,failure was because the ablation catheter could not be advanced to the SOO within the AIV.No complications occurred.QRS duration of PVCs/VT was 148.33 ± 18.09 ms,pseudo-delta wave was present in 4 patients.Maximum deflection index was 0.67 ± 0.27.One VT SOO within the PLV QRS complex positive in leadⅠ,and QRS complex predominantly negative in leadⅠin all other successful patients.A q wave in lead I(QWL I) were seen in 5 patients with PVCs/VT were successful eliminated in the GCV.SOO within the GCV precordial R-wave transition in lead V1,exhibited a right bundle branch block QRS morphology;SOO within the AIV precordial R-wave transition in V3,exhibited a left bundle branch block QRS morphology.During a follow-up period of 1 to 10 months,1 PVCs recurred(total number of PVCs: 3982 beats during 24 h),success rate was 75%.Conclusion The presence of a q wave in lead I and MDI≥0.6 maybe an important morphology criteria for ventricular arrhythmias originating from the GCV.The SOO of epicardial arrhythmias can be ablated from within the CVS in approximately 75% of patients.
What problem does this paper attempt to address?