Optimum Friction Factor for Roof-Friction Tuned Mass Damper

Jiaru Qian
2002-01-01
Abstract:In a roof friction tuned mass damper (TMD) system, the building roof was employed as a mass with the friction between the roof and its support members as the damper. This paper analyzed the vibration reduction caused by the friction with fuzzy optimization of the friction coefficient. The numerical analysis showed that the roof friction TMD system reduced the first mode peak response of the building subjected to ground motion by 60% and that the other mode responses were effectively controlled. The analysis also showed that for moderate intensity excitation by the ground motion with a friction coefficient not larger than 0.5, the optimum friction factor reduced the structural response by 30% which was 17% of the total reduction. Therefore, the roof based TMD is an effectire method for using friction to dissipate energy.