RF Tests of an 805 MHz Pillbox Cavity at Lab G of Fermilab
Derun Li,J. Corlett,R.A. MacGill,J. Wallig,M. Zisman,A. Moretti,Z. Qian,V. Wu,Robert Rimmer,J. Norem,Y. Torun
2003-01-01
Abstract:RF TESTS OF AN 805 MHZ PILLBOX CAVITY AT LAB G OF FERMILAB* Derun Li, J. Corlett, R. MacGill, J. Wallig, M. Zisman, LBNL, Berkeley, CA 94720, USA A. Moretti, Z. Qian, V. Wu, FNAL, Batavia, IL, USA R. Rimmer, Jefferson National Accelerator Facility, Newport News, VA, USA J. Norem, ANL, Argonne, IL, USA Y. Torun, Illinois Institute of Technology, Chicago, IL, USA Abstract We report recent high power RF tests on an 805 MHz RF pillbox cavity with demountable windows for beam apertures at Lab G of Fermilab, a dedicated facility for testing of MUCOOL (muon cooling) components. The cavity is installed inside a superconducting solenoidal magnet. A 12 MW peak RF power klystron is used for the tests. The cavity has been processed both with and without magnetic field. Without magnetic field, a gradient of 34 MV/m was reached rather quickly with very low sparking rate. In a 2.5 T solenoidal field, a 16 MV/m gradient was achieved, and it had to take many weeks of conditioning. Strong multipacting effects associated with high radiation levels were measured during the processing with the magnetic field. More recently Be windows with TiN-coated surface have been installed and tested at conditions of with and without the external magnetic field. A conservative 16 MV/m gradient without magnetic field was reached quickly as planned. Less multipacting was observed during the conditioning, it indicated that the TiN-coated surface on the windows had indeed helped to reduce the secondary electron emissions significantly. A modest gradient of 16.5 MV/m was finally achieved with magnet on in solenoidal mode and the field up to 4 T. Preliminary inspection on Be windows surface found no damage at all, in comparison with Cu windows where substantial surface damage was found. Preliminary understanding of conditioning cavity in a strong magnetic field has been developed. More through window and cavity surface inspection is under way. the peak surface field down and at the same time to provide high shunt impedance with large beam iris needed for muon beams. Taking advantage of muon beam’s penetration property, closed cell RF cavity was proposed [2] where the large beam iris may be terminated by thin low Z conducting material, say Be foil. The closed cell cavity resembles to a cylindrical pillbox cavity where peak surface field is the same as the peak acceleration filed on beam axis. Furthermore the cavity allows for choices of phase advance per cavity, which in turn offers independent phase control of each cavity so that provide more freedom for beam dynamics design. Efforts have been put on design of such a high gradient cavity, it has bean an engineering challenge on how to incorporate thin Be windows in the cavity. Conditioning and operating a RF cavity in strong magnetic field of a few-T have never been done before, strong magnetic field could pose potential difficulty in overcoming multipacting zones, surface damage and many possible unknowns. As part of ongoing R&D activity for the high gradient RF cavity for muon beams, we have designed and constructed an 805 MHz pillbox cavity with demountable windows [3]. The cavity design allows for tests of different windows. The cavity has been under high power RF tests at Lab G, FNAL since March 2002. In this paper, we report recent test results and future plans. Preliminary data analysis will be presented. Surface inspection and analysis of windows are being analyzed, and is reported in another paper at this conference [4]. THE 805 MHZ CAVITY INTRODUCTION Accelerators for intense muon beams call for uses of very high gradient RF cavities at various frequencies. The high gradient is a must to manipulate muon beams that are created large in 6-D phase space, and decay fast (muon lifetime is about 2 µs at rest). Any manipulation to muon beams has to be done quickly including cooling. For instance, muon cooling channel design for Study-II [1] calls for accelerating gradient of ~ 16 MV/m at 201 MHz, compared to ~ 15 MV/m of Kilpatrick criterion at the same frequency. Moreover these cavities have to be installed inside superconducting magnet where magnetic fields are as high as a few-T. Therefore normal (warm) conducting RF cavity technology has to be used, but the peak surface field of the cavity has to be further reduced in order to achieve the required high acceleration gradient provided using normal open iris RF cavities. However cavity geometry optimization is not good enough to bring The 805 MHz pillbox cavity was reported before [3]. The cavity and its power coupler were designed at LBNL using MAFIA code in frequency and time domain, respectively. Good agreements were achieved between the design values and low power RF measurements. The cavity body was fabricated at University of Mississippi, final cavity braze was carried out at Alpha-Braze company in Fremont, California. Final cavity cleaning, assembly, system integration and vacuum checking were conducted at LBNL. Four pre-stressed flat Be windows were purchased from Brush-Wellman Company in Fremont for tests. The cavity was shipped to Lab G of Fermilab for high power tests in March 2002. Table 1 lists main RF parameters of this cavity in comparison with the last low power RF measurements at Lab G. Work supported by the US Department of Energy under contract No. DE-AC0376SF00098