Assessment of Acquiring Kidney Tissue by Endoscopic Ultrasonography Guided Trucut Biopsy

Bo Sun,Xiaoying Zhu,Xiong-wei Dong,Jian Huang,Ji-sheng Yao,Zhao-Wen Yan,Qi Zhu
2006-01-01
Abstract:Objective To evaluate the efficiency and safety of acquiring kidney tissue by endoscopic ultrasound-guided Trucut biopsy (EUS-TCB). Methods Under general anesthesia, three 25-30kg swine underwent EUS examination. The kidney biopsy specimens were obtained by EUS-TCB and embedded in paraffin followed by hematoxylin and eosin stain and evaluated histopathologically. The length of tissue and the total number of glomeruli were counted. The animals were sacrificed after EUS-TCB to examine the overt bleeding in their abdominal cavities. Results Histopathological review demonstrated adequate samples representative of the organ biopsied, 81% (13/16) of biopsies provided tissue cores with an average of 5.3 times per each animal. The length of tissue ranges from 0.95-7mm ( mean 3.64 ± 1.73mm) and a total of 46 glomeruli (range:0-10) were obtained with an average of 3.5 ±2.9 per each biopsy. None of the animals developed overt bleeding in their abdominal cavities. Conclusion EUS-TCB is an effective and safe measure to obtain kidney tissue cores for histopathological study. Key words: Endoscopic ultrasonography ; Kidney ; Biopsy