Effect of Different Thickness of Silica Film by Sol-Gel Method on Bond Strengths of Titanium Porcelain System

Yu Wang
2010-01-01
Abstract:Objective:To investigate the effect of different thickness of silica film by sol-gel method on bond strength of titanium porcelain.Methods:Pure titanium specimens were randomly divided into four groups:specimens of group one times,two times and four times were subjected to one,two and four cycles of spinning coating and heat treatment,Specimens of controls had no further surface treatment.The thickness of silica film was measured by profilometer.The middle areas of the specimens were veneered with Ti-22 super porcelain.The load of the specimens was measured by a three-point bending test according to ISO 9693.Results:The thicknesses of silica film of group one times,two times and four times were 1.43±0.01μm,2.40±0.02μm and 4.00±0.02μm;The maximum load of group one times、two times、four times and control were 6.040±0.798N,5.604±0.742N,6.081±0.947N and 8.816±0.923N respectively.Conclusion:Different thicknesses of silica film have adverse effect on bond strength of titanium porcelain.