Advanced Treatment of Landfill Leachate by Integrated Process of Catalytic Micro-Electrolysis and BAF

Yang Chun-ping
2011-01-01
Abstract:Applying integrated process of catalytic micro-electrolysis-BAF to treat matured landfill leachate further.By orthogonal array experiments,it was confirmed that the optimal volume ratio of iron slag and coke was 1∶3,the optimum PH under the acid condition was 3,the optimum weight ratio of H2O2 and COD was 1.5∶1,the optimum PH under the alkaline condition was 7.5,the optimum reaction period of the micro-electrolysis was 1.5h,the optimum depositing period after adding H2O2 was 1.5 h,the optimum depositing period after regulating the wastewater under the alkaline condition was 2.0 h,removal rates of COD and chroma could reach 85% and 95% respectively,BOD5/COD was increased from 0.03 to 0.35 in continuous feed experiments.It improve biodegradable ability of the leachate in order to create a suitable condition for biological-chemical treatment next step.By this integrated process,the discharge of matured landfill leachate finally was up to the related national standards.