EXPERIMENTAL EVALUATION OF A TYPICAL BRIDGE COLUMN FOOTING DESIGNED TO CURRENT CALTRANS STANDARDS

Yan Xiao,M. J. N. Priestley,Frieder Seible
1995-01-01
Abstract:This report presents experimental background for evaluating the seismic performance of post-1971 design bridge footings. A model pier was tested in a vertical cantilever condition with cyclic horizontal displacements and constant axial load applied on the top of the column. Rubber pads were used to support the pier in order to simulate the actual compressive flexibility of pile supports, while high tensile strength bars were used to simulate the uplift stiffness of the piles. Results from tests and analyses indicated some potential problems in current footing design procedures. This was especially evident in the lack of the column/footing joint shear design and non- conservative flexural design that uses the full footing width.
What problem does this paper attempt to address?