Abstract:Ozone and activated carbon were used to treat the Yellow River water.The oxidation efficiency of organic pollutants was analyzed in different concentrations of ozone.A self-designed static reaction system was established,two ways to control the ozone dosage.The result showed that with doses of ozone between 1 mg·L-1 and 5 mg·L-1,the removal rates CODMn from 8% increase to 20%,did not change significantly more this.The removal rates UV254 from 9% increase to 36%,which lots of organic compounds can be removed.When ozonation dose was 1~2 mg·L-1,the short-term,high aeration intensity,removal rates of CODMn and UV254 were better.But increase ozonation dose,the longer aeration time was useful for romovel of organic pollutant,effectiveness can be increase.Under the condition that,the dosage of activated carbon was10 mg·L-1,the pH value was 8.3,the temperature was about 45 ℃,the doses of ozone was 3 mg·L-1,the adsorption capacity was stronger.It was indicated from the experiment that when the ozone dosage was 8 mg·L-1,the removal rate of TOC was 10%,far lower than CODMn and UV254.However the ozone dosage was 5 mg·L-1,BDOC increased by 80%.Therefore,the ozonation can improve biodegradability of water,provide the follow-up biological treatment with the conditions of organic nutrients.