Critical Frequency and Critical Stretching Rate for Reorientation of Cells on a Cyclically Stretched Polymer in a Microfluidic Chip
Tianjiao Mao,Yingning He,Yexin Gu,Yuqian Yang,Yue Yu,Xinlei Wang,Jiandong Ding
DOI: https://doi.org/10.1021/acsami.0c21186
2021-03-19
Abstract:The ability of cells to sense and respond to mechanical signals from their surrounding microenvironments is one of the key issues in tissue engineering and regeneration, yet a fundamental study of cells with both cell observation and mechanical stimulus is challenging and should be based upon an appropriate microdevice. Herein we designed and fabricated a two-layer microfluidic chip to enable simultaneous observation of live cells and cyclic stretching of an elastic polymer, polydimethylsiloxane (PDMS), with a modified surface for enhanced cell adhesion. Human mesenchymal stem cells (hMSCs) were examined with a series of frequencies from 0.00003 to 2 Hz and varied amplitudes of 2%, 5%, or 10%. The cells with an initial random orientation were confirmed to be reoriented perpendicular to the stretching direction at frequencies greater than a threshold value, which we term critical frequency (<i>f</i><sub>c</sub>); additionally, the critical frequency <i>f</i><sub>c</sub> was amplitude-dependent. We further introduced the concept of critical stretching rate (<i>R</i><sub>c</sub>) and found that this quantity can unify both frequency and amplitude dependences. The reciprocal value of <i>R</i><sub>c</sub> in this study reads 8.3 min, which is consistent with the turnover time of actin filaments reported in the literature, suggesting that the supramolecular relaxation in the cytoskeleton within a cell might be responsible for the underlying cell mechanotransduction. The theoretical calculation of cell reorientation based on a two-dimensional tensegrity model under uniaxial cyclic stretching is well consistent with our experiments. The above findings provide new insight into the crucial role of critical frequency and critical stretching rate in regulating cells on biomaterials under biomechanical stimuli.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acsami.0c21186?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acsami.0c21186</a>.Note 1: introduction and formula derivation of two-dimensional tensegrity model of cell reorientation; schematic diagrams of a simplified two-layer chip versus a conventional three-layer chip; manufacturing process of a two-layer microfluidic device or chip; photographs of two working chips and the integrated system for cell cyclic stretching; chemical structure and cross-linking reaction of SU-8; cross-linking reaction of polydimethylsiloxane (PDMS); the optimal parameters of the microfluidic stretching device; characterization of the strain amplitude of the microfluidic stretching device; fluorescence micrographs of human mesenchymal stem cells (hMSCs) to examine the response of cell cytoskeleton (microfilament, microtubule, and intermediate filament) to uniaxial cyclic stretching; distribution of orientation angles (θ) of hMSCs after 10 h cyclic stretching for stretching experiments with different amplitudes and frequencies; order parameter of cells <i>S</i> as a function of stretching time at different frequencies and fixed amplitudes (2%, 5%, or 10%); variation of the order parameter <i>S</i> with time; order parameters at steady state (<i>S</i><sub>st</sub>) as a function of amplitude; cell area and shape descriptors of hMSCs at different amplitudes; time course of the displacement of the PDMS elastic membrane upon cyclic uniaxial stretching; the <i>p</i> value of two-tailed <i>t</i>-tests by comparing each of the stretched groups (stretching amplitude: 2%, 5%, or 10%) with the control group with respect to angles of reorientation; stretching rates of different types of cells calculated by us based on the raw data in the literature (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c21186/suppl_file/am0c21186_si_002.pdf">PDF</a>)Movie S1: video of phase contrast micrographs to show the reorientation process of hMSCs (<a class="ext-link" href="/doi/suppl/10.1021/acsami.0c21186/suppl_file/am0c21186_si_001.mp4">MP4</a>)This article has not yet been cited by other publications.
materials science, multidisciplinary,nanoscience & nanotechnology