Experimental Study on Hysteretic Behavior of Shear Panel Dampers Made of Steel with Low Yield Point
Zhong-shuang SONG,Ji-long LI,Lu HAN,Hui LI,Jin-ping OU
DOI: https://doi.org/10.13409/j.cnki.jdpme.2014.03.009
2014-01-01
Abstract:To improve the not obvious performance of energy dissipation of residual hysteretic dampers in the condition of small vibration deformation,five shear panel dampers made of domestic low yield point steel(LYPSSP)were designed,and low reversed cyclic tests were carried out to investigate the hysteretic behavior,in which the effects of core panels′connection,widththickness ratio,cross stiffeners were considered.The study shows that penetration weld connection of core panels versus flanges is more simple structure,higher reliability and easier to process,when compared to bolted connection;the dampers have full hysterical curves,perfect energy dissipation behavior,and great stability because of the similarity of hysterical curves in the same loading levels,and very obvious phenomenon of hardening in the process of cyclical loading,and dampers′strength and stiffness have no sudden change before failure;when taking P/Pyas the design goals,the smaller the width-thickness ratio of core panels and out-plane buckling,the more full the hysterical curves and the better the energy dissipation behavior will be;the equivalent viscous damping coefficient and average energy-dissipating coefficient can give the accurate judgment to the behavior of energy dissipation of dampers.