Abstract:A method for determination of nicotine content in tobacco by a reverse phase HPLC was established.The content of nicotine in samples was investigated.The column was Kromasil C18 column(250 mm×4.6 mm,5 μm)and temperature was 35 ℃,methanol(A)-TEA/phosphate buffer(B)(2.42 g Na2HPO4,3.5 mLH3PO4 and 6.5 mL TEA dissolved in 1 000 mL H2O)(A∶B 3∶2,V/V) as the mobile phase at a flow rate of 1 mL·min-1 and the detection wavelength at 259 nm.The results showed that the precision,stability,repetition and sensitivity were good.The RSD,coefficient of variation,linear correlation and average recovery were 0.014,1.2%,1.0 and 98.8%,respectively.