Comparative Study of High Intensity Focused Ultrasound(hifu) with Loop Electrosurgical Excision Procedure(leep)in the Treatment of the Cervical Intraepithelial Neoplasiai(cini)

Yan Ya
2013-01-01
Abstract:Objective To compare the effectiveness and safety profile of high intensity focused ultrasound(HIFU) verses Loop Electrosurgical Excision Procedure(LEEP) in the treatment of CINⅠ.Methods90 cases of CIN Ⅰ diagnosed by punch biopsy and pathological confirmation of postoperative specimens between March 2010 and June 2012 were reviewed and analyzed,in which 45 cases underwent the loop electrosurgical excision procedure(LEEP),45 patients adopted high intensity focused ultrasound(HIFU).ResultsThe patients treated with HIFU have less operation time,less operative bleeding,and reduced white discharge.The efficacy of HIFU was found to be 88.9%(40/45) and that of LEEP was 91.2%(41/45)which is not significantly different.Two women with persistent lesion after HIFU,less than LEEP,which is five.The recurrence rate was higher after LEEP(11.1%) than after HIFU(2.2%).The value of HPV in HIFU group decreased more than LEEP group,with the statistically significant difference between them(P 0.05).ConclusionFocusing ultrasonic therapy is a kind of safe and effective method for the treatment of cervical intraepithelial neoplasiaⅠ.
What problem does this paper attempt to address?