Empirical Copula-based Anomaly Detection of Dynamic Runtime Parameters

SONG Ke,QIAN Tang-jiang,WU Bin,CHEN Yong-xu,ZHONG Ting,ZHOU Fan
DOI: https://doi.org/10.3969/j.issn.1671-1815.2023.33.022
2023-01-01
Abstract:As a result of the development of industrial intelligence,intelligent control systems have been equipped in industrial pro-duction systems,and one of the important requirements is intelligent anomaly detection.However,achieving intelligent anomaly detec-tion is often difficult due to the streaming data format of dynamic runtime parameters and the coupling of high-dimensional data,which make it challenging to perform reliable and efficient anomaly detection.To this end,this paper proposes an anomaly detection method based on joint distribution.Firstly,the dynamic operating data was sampled from both real-time detection and overall detection per-spectives.Then,the joint distribution was modeled using empirical Copula.Finally,the anomaly score was determined based on the model.The dataset of the drainage system in a hydropower station on Dadu River was used to investigate the effectiveness of the pro-posed method,and the results show that this method is more efficient than traditional anomaly detection methods and improves area un-der curve(AUC)value and average precision.Meanwhile,the interpretability of this method also provides a reliable basis for subse-quent troubleshooting and maintenance of the drainage system.
What problem does this paper attempt to address?