Torque Calculation of Surface-Mounted Permanent-Magnet Motors Using Subdomain Model Considering Finite Permeability: Influence of Harmonic Content

Che Sun,Youtong Fang,Pierre-Daniel Pfister
DOI: https://doi.org/10.1109/icems59686.2023.10344332
2023-01-01
Abstract:In this article, a subdomain model of surface-mounted permanent-magnet motors considering finite magnetic permeability is studied. Four machines with different pole pairs are used to assess the influence of the harmonic content on the torque calculation of that model. This study shows that only a few harmonics are needed to have high accuracy in torque calculation, while the magnetic flux density needs more harmonic to ensure higher accuracy. For the different permeabilities tested, the accuracy of the toque calculation mainly depends on the harmonic in the PMs and airgap regions.
What problem does this paper attempt to address?