EPD-iSCAT: Electrophoretic Mass Photometry

Matthew Kowal,Teresa Seifried,Carraugh Brouwer,Hooman Tavakolizadeh,Edward Grant,Erik Olsén
DOI: https://doi.org/10.26434/chemrxiv-2023-ddzfc-v2
2023-12-18
Abstract:Interferometric scattering microscopy (iSCAT) has rapidly developed as a quantitative tool for the label-free detection of single macromolecules and nanoparticles. In practice, this measurement records the interferometric scattering signal of individual nanoparticles in solution as they land and stick on a coverslip, exhibiting an intensity that varies linearly with particle volume, and an adsorption rate that reflects the solution-phase transport kinetics of the system. Together, such measurements provide a multidimensional gauge of particle size and concentration in solution over time. However, the landing kinetics of particles in solution also manifest a measurement frequency limitation imposed by the slow long-range mobility of particle diffusion to the measurement interface. Here we introduce a new technique that offers a novel means to overcome the inherent diffusion-controlled sampling limitation of spontaneous mass photometry. We term this methodology, electrophoretic deposition interferometric scattering microscopy (EPD-iSCAT). This approach uses a coverslip supporting a conductive thin film of indium tin oxide (ITO). Charging this ITO film to a potential of around 1 V electrophoretically draws charged nanoparticles from solution and binds them in the focal plane of the microscope. Regulating this potential offers a direct means to control particle deposition. Thus, we find for a 0.1 nM solution of 50 nm polystyrene nanoparticles that the application of +1 V to an EPD-iSCAT coverslip assembly drives a electrophoetic deposition rate constant of 1.7 s−1 μm−2 nM−1. Removal of the potential causes deposition to cease. This user control of EPD-iSCAT affords a means to apply single-molecule mass photometery to monitor long-term changes in solution owing to slow kinetic processes. In contrast with conventional coverslips chemically derivatized with charged thin films, EPD-iSCAT maintains a deposition rate that varies linearly with bulk concentration.
Chemistry
What problem does this paper attempt to address?
The paper mainly addresses the following issues: ### Research Background and Challenges - **iSCAT Technology**: Interferometric Scattering Microscopy (iSCAT) is an effective tool for label-free detection of single nanoparticles, capable of achieving precise resolution in time, space, and molecular mass. - **Diffusion Limitation**: In traditional iSCAT measurements, the Brownian motion of particles in solution spontaneously drives them close to the coverslip, but this process is limited by the frequency of the slow long-range movement of particles diffusing to the measurement interface. ### Solution - **EPD-iSCAT Technology**: A new technique called Electrophoretic Deposition Interferometric Scattering Microscopy (EPD-iSCAT) is introduced. By supporting a conductive indium tin oxide (ITO) film on the coverslip and applying a potential of about 1 volt, charged nanoparticles are electrophoretically attracted from the solution to the microscope's focal plane and bound there. - **User Control**: By adjusting the potential, users can directly control the deposition process of particles, allowing EPD-iSCAT to overcome the sampling limitations caused by diffusion control in traditional iSCAT. - **Linear Relationship**: Unlike traditional chemically modified coverslips, EPD-iSCAT maintains a deposition rate that is linearly related to the particle concentration in the solution. ### Main Contributions - **Experimental Validation**: Experiments with polystyrene nanoparticles confirmed that the potential gradient can periodically turn the solute binding process on or off, and the deposition rate is linearly related to the solute concentration in the solution. - **Advantages of the New Technology**: EPD-iSCAT unlocks a new dimension of experimental control, allowing direct sampling control. This enables iSCAT technology to be applied to a range of new techniques, especially those involving biological systems, nanoparticle synthesis, and automated micro-detection of slow time-dependent events. Through these methods, researchers have addressed the diffusion limitation problem in traditional iSCAT technology, enhancing the flexibility and application range of single-particle detection.