Prior Active Shape Model for Detecting Pelvic Landmarks

Chenyang Lu,Wei Chen,Qiao Xu,Qingyun Zeng
2023-01-01
Abstract:Measurement of pelvic landmarks is a standard analytical tool for diagnosis and treatment prognosis. The purpose of this study is to develop and verify an automatic detection system for detecting pelvic measurement landmarks on pelycograms. Pelycograms for 430 subjects were available. All images have 17 landmarks. In this paper, a deep neural network system with Active Shape Model (ASM) prior knowledge is proposed that can be used to automatically locate landmarks on pelycograms. The outline of the pelvis is obtained by ASM, and the landmarks are roughly detected. Then the landmarks are accurately detected by a depth neural network based on this prior knowledge. The system is evaluated by experiments, and the average radial error of the system is 4.159 mm and the standard deviation is 5.015 mm. 81.353% of the landmarks are within the clinically acceptable precision of 6 mm. At the same time, the integration of ASM prior knowledge also improves the detection accuracy by 1.007 mm. This method can quickly and accurately locate landmarks in pelycograms, and it is possible to significantly improve the clinical workflow of orthopedic treatment.
What problem does this paper attempt to address?