Economic and Heating Efficiency Analysis of Double-Shell Downhole Electric Heater for Tar-Rich Coal In-Situ Conversion

Wei Guo,Zhendong Wang,Fu Yang,Deliang Fu,Ma Li,Zhonhui Duan,Qiuwang Wang
DOI: https://doi.org/10.2139/ssrn.4056995
2022-01-01
SSRN Electronic Journal
Abstract:Tar-rich coal in-situ conversion is the trend of cleaning and efficient use of coal resources, temperature (heat) is a key factor in the tar-rich coal in-situ conversion. The closed double-shell structure is proposed in this paper. Four downhole electric heaters were experimentally studied, and the single-shell heater was used as the control. According to the experimental results, the mass flow rate has a great impact on the total cost, and the parallel double-shell downhole electric heater has the highest total cost. In addition, the larger the pitch or the heater shell diameter, the higher the surface temperature of the heating rod. Compared with double-shell heater, single-shell heater has higher total heat loss. Thermal radiant is the main way of heater shell to lose heat, which is accounts for 78.91%-92.91%. Moreover, from the perspective of heat transfer quality, heater with closed double-shell structure is more efficient than the single-shell heater, and the energy utilization efficiency of heater with closed double-shell structure achieves 97.38%-99.59%. Taking the comprehensive cost of in-situ exploitation of tar-rich coal into account, the small outer shell diameter is an optimal choice for the heater with closed double-shell structure.
What problem does this paper attempt to address?