Simulation study on effects of longitudinal ventilation on smoke exhausting performance of tunnel shafts
Tonghui JIANG,Haiyong CONG,Xiangxiao KONG,Guochun LI,Qiong TAN,Xishi WANG
DOI: https://doi.org/10.3969/j.issn.1004-5309.2018.01.02
2018-01-01
Fire Safety Science
Abstract:This paper investigated the effects of longitudinal ventilation on exhausting efficiency of the shafts with different heights,and determined the optimal ventilation velocity by scaled experiments and FDS numerical simulations.The critical conditions of plug-holing were discussed through analyzing the effects of ventilation velocity and shaft height on plug-holing and boundary layer separation.Five ventilation velocities (0.096,0.226,0.356,0.485,0.629 m/s)and 4 heights of the shaft (0.133,0.2,0.333,0.533 m),were considered in the scaled experimental tests.The experimental results showed that when the ventilation velocities were 0.096,0.226,0.356 m/s (corresponding to the actual wind speed of 0.37,0.87,1.38 m/s), plug-holing could be restrained,but the boundary layer separation of the smoke would be aggravated with increase of the ventilation velocity.The critical criterion of plug-holing,i.e.,Fcritical= 1.5,was not applicable under the tested longitudinal ventilation conditions,while Ri′critical= 1.4 was still applicable.The simulated results indicated that the smoke exhaust rate decreased with increase of the longitudinal ventilation velocity when shaft heights were 1 ,1.5 and 2 m.For shaft height over 3 m,however,the smoke exhaust rate increased first and then decreased with increase of the longitudinal ventilation velocity when shaft heights were 3,4 and 5 m,and the maximum value occurred at 1.5 m/s.