A Microcoulometric Method for Determination of Absorbable Organic Halogenidesin Environmental Water

Ren Li
2002-01-01
Abstract:It has been recognized that absorbable organic halogenides ( AOX) is a complex index capable of evaluating the quality of environmental water bodies,and indicate pollution levels in environmental water bodies. Our experimental results showed that the lowest detected concentration by this method could reach to 0.002 mg Cl·L-1, with averaged recoveries by sample spiked of 97.9%-103.8%, and variation coefficient of 1.38%- 3.19%, and the run time wasbetween 5 -20 min , respectively, for different sample analysis. This method is characterized by simplicity, speediness, good accuracy and precision, and is suitable for analysis of organic halogens in environmental water bodies.