Optimization of Operating Conditions of PAC /UF Process

Feng Li
2013-01-01
Abstract:The combined powder activated carbon(PAC) and immersed ultrafiltration membrane(UF) process was applied to treatment of the raw water from a reservoir in Shenzhen.The effects of PAC dosage,discharge cycle and aeration intensity on the removal of organic compounds and membrane fouling were investigated to optimize the operating conditions of the combined process.The results indicated that PAC enhanced the removal of organic compounds.The effect was optimum at a dosage of 10 mg/L,and the removal rates of CODMn and UV254 were 42% and 35%,respectively.The PAC gradually reached saturated adsorption in membrane tank,and the removal rates of CODMn and UV254 were reduced by 3% and 5%,respectively.The discharge cycle of 24 h was good for the system to keep a relatively high removal effect of organic compounds.A relatively strong aeration intensity with a gas/water ratio of 12 ∶ 1 enhanced the removal of organic compounds,slowed down the formation of membrane cake layer and alleviated pore fouling.