Layered Uranyl Phosphonate As A Dual-response Luminescence Thermometer★

Wen Ge-Hua,Wendurina,Chen Xiumei,Ma Xiu-Fang,Weng Guo-Guo,Wei Yi-Fan,Bao Song-Song,Xie Xiaoji,Hu Shu-Xian,Zheng Li-Min
DOI: https://doi.org/10.6023/a23050242
2023-01-01
Acta Chimica Sinica
Abstract:Luminescent uranyl phosphonate coordination polymers have been used for temperature sensing but have not yet been used for dual-response luminescence thermometers. Herein we report a luminescent uranyl phosphonate based on 2-(phosphonomethyl)benzoic acid (2-pmbH3), namely, (alpha-C8H12N)[UO2(2-pmb)] (1). This compound crystallizes in monoclinic space group C2/c and shows a layered structure. Within the layer, the uranyl ions are doubly bridged by O-P-O and O-C-O unis forming chains. The equivalent chains are cross-linked through corner-sharing of UO7 pentagonal bipyramids and PO3C tetrahedra forming a layer. The adjacent U center dot center dot center dot U distances within the layer are 0.5414 and 0.5743 nm. The organic groups of the 2-pmb3- ligand reside on the two sides of the layer. The interlayer space is filled with the racemic protonated phenethylamine cations to charge-balance the anionic layer. The shortest U center dot center dot center dot U distance between the layers is 1.239 nm. Compound 1 exhibits high thermal and water stability, especially in aqueous solution at pH 5 similar to 11 and in boiling water. The UV-Vis spectrum of 1 shows two broad bands peaking at 320 and 412 nm. The scalar-relativistic density functional calculations reveal that the two bands are associated with ligand-to-metal charge transfer (LMCT) transitions from ligand orbitals to metal orbitals lower-fd (fz( x2-y2)). Photoluminescence properties show that 1 emits green-light at room temperature with six emission peaks at 481, 500, 516, 540, 564 and 591 nm, assigned to the electronic and vibronic transitions of S-11-S-00 and S-10-S-0 nu (nu= 0 similar to 4). Interestingly, both the emission intensity and the lifetime of compound 1 are temperature-dependent, making it possible to be used as a dual-response luminescence thermometer in the temperature range of 200 similar to 360 K. The intensity-dependent maximum sensitivity is 2.96%.K-1 (330 K) and the lifetime-dependent maximum sensitivity is 2.51%.K-1 (350 K), which are comparable to some lanthanide-based luminescent thermometers. This work provides a rare example of uranyl coordination polymers that can be used as a dual-response luminescence thermometer with wide operating temperature and good sensitivity.
What problem does this paper attempt to address?