An Investigation on Spatiotemporal Sizes of Specific Types of Lightning Flashes

Yun Pan,Dong Zheng,Yijun Zhang,Gaopeng Lu,Wen Yao,Wenjuan Zhang
DOI: https://doi.org/10.1029/2022jd038191
2023-01-01
Abstract:The duration and horizontal extension distance (HED) of intracloud (IC), negative cloud-to-ground (NCG), positive cloud-to-ground (PCG), and bipolar cloud-to-ground (BCG) lightning are analyzed using data from the Oklahoma Lightning Mapping Array and the National Lightning Detection Network. All of these conform to lognormal distributions. BCG lightning has the greatest average spatiotemporal size, owing to its longest-duration and largest-spatial-extension discharge process after the first return stroke (RS). Compared with NCG lightning, PCG lightning tends to include longer-duration and greater-spatial-extension discharge processes before the first RS, making the latter have a larger average spatiotemporal size. IC lightning exhibits the smallest average spatiotemporal size, with a higher concentration of samples in smaller size intervals. Overall, as lightning initiation heights increase, IC and NCG lightning duration tends to increase, while NCG lightning variation is mainly due to discharge processes before the first RS. HED of both types initially increases and then decreases, peaking at similar to 7 km. The horizontal extension speed (HES) of IC lightning tends to decrease with increasing initiation height, while for NCG lightning, the HES associated with discharge processes before the first RS shows a clearer decreasing trend at higher levels. The NCG lightning initiated below similar to 6 km tends to exhibit similar HED before the first RS and increased HED after the first RS. However, for NCG lightning initiated above similar to 6 km, the HED before the first RS is notably greater than the increased HED after the first RS. This study examines the duration of discharge processes and horizontal extension distance (HED) of intracloud (IC) lightning, which propagates only within or between clouds, and cloud-to-ground (CG) lightning, including positive cloud-to-ground (PCG), negative cloud-to-ground (NCG), and bipolar cloud-to-ground (BCG) lightning, which transfers positive, negative, and both positive and negative charges to the earth via one or more grounded channels, respectively. On average, BCG lightning exhibits the largest spatiotemporal size, followed by PCG, NCG, and IC lightning. CG lightning is divided into two stages: discharge processes before and after the first return stroke (RS), an intense neutralization process when the channel first connects the cloud and earth. In the first stage, PCG lightning typically exhibits a greater spatiotemporal size than NCG lightning. In the second stage, BCG lightning has a significantly larger spatiotemporal size than both PCG and NCG lightning. Higher-initiated IC and NCG lightning tend to have a longer duration and smaller horizontal extension speed than lower-initiated lightning. IC and NCG lightning both tend to have larger HED at middle levels. For NCG lightning initiated above similar to 6 km, the discharge process before the first RS contributes more to the HED. The study uncovers how the spatiotemporal sizes of intracloud (IC) and negative cloud-to-ground (NCG) lightning flashes change as the lightning initiation height increasesBipolar cloud-to-ground (BCG) lightning has the largest spatiotemporal size on average, followed by positive cloud-to-ground (PCG), NCG, and IC lightning in that orderLarger sizes of PCG and BCG lightning primarily benefit from the discharge processes before and after the first return stroke, respectively
What problem does this paper attempt to address?