Development, Validation, and Implementation of an Ultratrace Analysis Method for the Determination of Moenomycin A, in Aquatic Animal Products.

Yunyu Tang,Guangxin Yang,Yingqing Ma,Dongmei Huang,Wenlei Zhai,Essy Kouadio Fodjo,Xuan Zhang,Siman Li,Weiyi Zhang,Yongfu Shi,Cong Kong
DOI: https://doi.org/10.1007/s00216-023-04965-4
2023-01-01
Analytical and Bioanalytical Chemistry
Abstract:Moenomycin A, an antimicrobial growth promoter widely used as an additive in aquaculture feedstuffs, has been restricted for use in the European Union and China due to its potential risk of promoting resistant strains of pathogenic bacteria and causing residues in aquatic animal products. Although methods for analyzing moenomycin A in feedstuffs have been developed, no established method exists for aquatic matrices. In this study, we present, for the first time, a sensitive and validated high-performance liquid chromatography-tandem mass spectrometry (HPLC–MS/MS) method for the determination of moenomycin A in aquatic animal products. Samples were extracted using methanol and purified with the QuEChERS method employing C18 sorbent. The aliquot was dried under a nitrogen stream, reconstituted with methanol-water solvent, and analyzed by HPLC–MS/MS. The developed method exhibited good linearity (r2 > 0.995) over a wide concentration range (1–100 μg/L) and a low limit of detection (1 µg/kg). Average recoveries ranged between 70 and 110
What problem does this paper attempt to address?