Study on Qualitative Imaging Diagnosis of Human Brain Glioma with Immuno-Radionuclide

Qiang Huang,Qing Lan,Xiaonan Li
1996-01-01
Abstract:The target imaging agent 131I-SZ39 was made by labelling to monoclonal antibody SZ39 with 131I using modified chloramine T method. On the basis of the biodistribution and pharmacokinetics study in glioma-bearing nude mice and the patients, the qualitative diagnosis of 40 cases with intracranial space-occupying lesion was compared with that of X-CT. The results were satisfactory. SZ39 could deliver 131I to the target cells specifically. The ratio of target tissues to nontarget tissues was 5.73~144.8 in the glioma-bearing animals and 2.97~3.25 in the patients at 72 h. The half life of the imaging agent in blood were 1. 6 h ( T1/2a ) and 39 h ( T1/2B).The clearing rate was 54% in blood and 80% in urine at 72 h. The sensitivity of target qualitative diagnosis was 92%. The accuracy was 82%. The positive prediction rate was 81% and the negative prediction rate was 91%. Those of X-CT were 46% , 45% , 57% and 33% respectively ( P 0. 01 ~ 0. 005 ).
What problem does this paper attempt to address?