Study on Leakage Current for Single Phase Transformerless PV Grid Connected System

Dehong Xu
2013-01-01
Abstract:Leakage current is very important for researching non-isolated photovoltaic grid connected system,and the building of equivalent model resonant circuit of leakage current is crucial for researching suppression of the leakage current.In this paper,the resonant circuit of leakage current equivalent model of single phase grid connected inverter is deduced firstly.Then,the principle of the generation of leakage current is analyzed in detail.It is shown that leakage current is impacted by different switch modulation techniques and the asymmetric distribution of filter inductor.The paper points out that the influence of grid voltage on leakage current can not be ignore.Finally,a novel transformerless topology is introduced,which has the advantages of unipolar and bipolar modulation.The structure not only can suppress common-mode leakage current,but also improve system efficiency and the quality of grid current.The correctness of theoretical analysis is verified by simulation and experiment.
What problem does this paper attempt to address?