Dynamic Magnetic Resonance Perfusion-Weighted Imaging in Rabbit Models of Implanted Hepatic VX_2 Tumor after Microwave Ablation

Guoxiang You,Xiaolin Zheng
2009-01-01
Abstract:Objective To investigate the possibility and feasibility of dynamic magnetic resonance(MR) perfusion-weighted imaging(PWI) in rabbit models of implanted hepatic VX2 tumor after microwave ablation.Methods MRI and PWI images were obtained from 12 rabbit models of implanted hepatic VX2 tumor and 4 normal rabbits at 1,7,14,and 28 days after tumor ablation,respectively,and the maximum slope of increase(MSI) was estimated and compared with pathological results.Results The mean MSI of the liver of experimental group showed no significant difference from that of the control group.The mean MSI of tumor in the experimental group before and after surgery showed no significant difference.On the same 1,7,14 and 28 days following surgery,the mean MSI of the tumor in experimental group and the benign enhancement tissue had significant differences.The time-intensity curves of the tumors were observed to be rapidly ascending and reaching a plateau,whereas the enhancement tissue curves ascend slowly to reach the plateau.Conclusion Dynamic PWI quantitative analysis of rabbit models of implanted hepatic VX2 tumor after microwave ablation provides valuable means for observing the pathology of tissues and may be clinically applicable in the evaluation of hepatic diseases.
What problem does this paper attempt to address?