Purity Determination of 1,3-Bis(2-hydroxyethoxy)benzene by Differential Scanning Calorimetry

Shaomin Zhang
2006-01-01
Abstract:The principle and experimental process for determining the purity of crystal substance by differential scanning calorimetry (DSC) are described. The applicability of Van't Hoff equation and DSC method to 1,3-bis(2-hydroxyethoxy)benzene(HER) samples is discussed. The purities of several HER products of different batches from different manufacturers were determined by DSC method. The deviations(absolute) between two parallel experimental results are not more than 0.1% if the purities(molar fraction) of samples are more than 98.0%. The determination results of import sample accorded with those by HPLC method. It was determined that the theoretical melting point of HER (infinite pure sample) is 89.48±0.05℃ and the fusion heat of HER is 39.4±0.7J/mol along with the purity determination.
What problem does this paper attempt to address?